· FAW-Volkswagen Automotive Co., Ltd. recalled some golf and sagitar cars

A few days ago, FAW-Volkswagen Automotive Co., Ltd. filed a recall plan with the AQSIQ according to the requirements of the Regulations on the Management of Defective Automobile Product Recall, and decided to recall the following vehicles from the date of 577,590 vehicles.
(1) Some golf A6 1.4T, 1.6L and 2.0T vehicles produced between September 10, 2009 and May 9, 2014, totaling 416,364 vehicles;
(II) Some of the sagitar 1.4T, 1.6L and 1.8T vehicles produced during the period from July 5, 2010 to March 1, 2012, totaling 161,226 vehicles.
Some vehicles within the scope of the recall, in the specific circumstances of high air humidity, rapid temperature changes and vibration, the fuses protecting the exterior lights may fail due to overheating, resulting in some exterior lights (such as the right front side low beam) Lamps, left rear brake lights, license plate lights, etc.) cannot work properly, posing a safety hazard. In this case, the vehicle circuit ensures that other lights around the vehicle continue to illuminate, and the display of the instrument cluster will alert the user to a light anomaly. FAW-Volkswagen Automotive Co., Ltd. will replace the improved light fuses for vehicles within the recall range to eliminate safety hazards.
The recall was carried out under the circumstances of the AQSIQ initiated defect investigation. For some time, the AQSIQ Defective Product Management Center received complaints from consumers about this issue. After receiving the complaint, the AQSIQ immediately deployed the Defective Product Management Center to conduct a defect investigation and assessment of the above issues. Affected by the investigation, FAW-Volkswagen Automotive Co., Ltd. decided to take recall measures to eliminate potential safety hazards.
FAW-Volkswagen Automotive Co., Ltd. will notify the owner of the vehicle by registered mail, etc., and will contact the relevant owner through an authorized dealer to arrange free maintenance. Users can use the landline or mobile phone to call the FAW-Volkswagen Customer Service Center hotline (400-817-1888) for consultation. Owners can also visit the AQSIQ Defective Product Management Center website () and the WeChat public account (AQSIQDPAC) for more information. In addition, you can also call the AQSIQ Defective Product Management Center hotline to reflect problems during the implementation of the recall or submit defects.

Automatic Sliding X-ray hospital Door

hospital door, hospital sliding door, medical sliding door , automatic medical airtigh door, clean room door ,operating theaters door

Hospital door

Medical sliding door , each door has a single whole steel plate , lined with aluminum profile inner frame and high strength honeycomb panels , surrounded by high quality stainless steel shut perfect treatment , high dimensional accuracy , closed surface made of high quality EPDM special rubber seal to be perfect seamless seal , Bao steel steel board used in all high-quality cold-rolled steel , the surface with high-quality weather-resistant color pure polyester electrostatic powder coating , its performance in line with GB5237.4-2000 standard (in line with European standards QUALICOA D), and the development of a variety of wood effect , Door Press (medical diagnostic X-ray emission prevention health protection requirements ) lining thickness corresponding stereotype . protective harness toward lining 2mmpb thickness , the thickness of the other 1mmbp protection , The vertical axis hinge design unique , different from the conventional hinge , changing the point of impact to avoid sagging door , making more durable protective door , you open smoothly

Automatic Medical Airtight Doors with airtight , Sound insulation , thermal insulation , fire protection , radiation protection

1 Using a small volume , high-power brushless DC motor , frequent opening and closing , also can be long-term trouble-free operation

2. The sides of the door equipped with professional vacuum airtight tape , using a unique compression technology to ensure the door when the door is closed with the close coordination to achieve reliable sealing effect

3. With foot switch and special handle , health care workers to open the door easily , when power outage it can be opened by handle

4. The Safety sensors can effectively prevent the clip people , also can be set to automatic door sensor drive from indoor

5. Also can be opened easily by a remote control

6. The user can set the sensor effects , the flexibility to set the sensor operation mode according to the doctor`s work habits and characteristics of various types of surgery , in order to achieve the best results

Designed for clean room environments such as hospital operating rooms , pharmaceutical production plants, precision equipment factories, food shop , laboratory access port

Technical parameters

Power Voltage : 220V/50HZ

Power consumption : <150w

Door weight :<200KG

Opening/Closing speed : 20-60cm/sec

Closed way: Auto/induction

Safety Light Beam Switch :

This is which accord with the European standards , with a completely interference immunity . Also accord with ESC standards and in line with the French government about the workplace regulations require automatic doors

Accord with German regulations concerning the outer doors of power starting

hospital door, hospital sliding door, medical sliding door , automatic medical airtigh door, clean room door ,operating theaters door

SHENZHEN HONGFA AUTOMATIC DOOR CO., LTD , https://www.hongfafrs.com