Flow Fluid Measured: Liquid, Air, Solid Flow
Output Signal: 4-20mA, Pulse, RS485, Hart
Indicate: Flow Rate, Total Flow, Density, Temperature
Fluid Types: Two-Phase Flow, Three-Phase Flow
Trademark: U-ideal
Origin: Tianjin, China
HS Code: 90261000
Mass Flow MetersMass flow+ volume flow+density +temperature measurement+calculated variables (e.g. fluid concentrations)Introduction of Coriolis flow meterÂ
(1) The Coriolis force mass flowmeter can measure the mass flow rate directly, and won't be affected by the measured medium temperature, pressure, density, viscosity. But Other kinds of mass flowmeter using indirect measurement method, to measure volume flow first, and then got the mass flow rate after compensation of temperature, pressure, density.(2) The Coriolis force mass flowmeter inside have no moving parts, high reliability; Don't need Straight pipe before and after the installation.(4) The Coriolis force mass flowmeter have options of all-in-one type and split type, LCD, explosion-proof type, temperature insulating model. Can output analog signal 4~20mA, the frequency signal, the RS485 communication interface and Hart protocol at the same time.(5) The Coriolis force mass flowmeter is suitable for various liquid, such as corrosive liquid, smudgy medium, suspension, two phase liquid (gas content in liquid <10% in volume, if air content big, please add air eliminator), etc.Â
Â
Coriolis Mass Flow Meters patented and developed by our company are the leading meters for precision flow measurement. And with good reason, the meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop. The meters offer direct mass flow, volume flow, density, and temperature measurement of liquids and slurries — without the need for additional equipment, manual calculations, or estimations.
Â
The meters carry hazardous area approval for P. R. China.
 Â
3. Warranty period: 12 months from the date of putting the instruments in operation, but not more than 18 months from the date of official shipment from our factory.Â
4. Medium: Liquid OR Gas 5. Main technical parameters
(1) Measurement scope: 2kg/h~500t/h
(2) Accuracy: ± 0.2%~± 0.15%
(3) Work pressure: (0~32) MPa (in case of other high pressure, it must be of special order)
(4) Medium temperature: -50º C~ +350º C,
Measurement accuracy: ± 1º C
(5) Environment temperature: -20º C ~ +70º C
(6) Measurement medium: Liquid, gas, solid, or two phases and three phases mixed fluid
(7) Output signal:
4-20mA current signal of flow, with load resistance ≤ 500Ω
0-10kHz frequency signal of flow.
RS485 Communication protocol
Hart protocol
(8) Power supply voltage: 24VDC
(9) Measurement of measuring pipe: 316L stainless steel
(10) Response time: 0.1s~5s, adjustable
(11) Explosion-proof grade: Ex(ib)II BT2-T5Working principle:The structure of Coriolis Mass Flow Meters was consisted of a pair of bended tubes. The principle is to detect Coriolis force forced a pair of tubes from inner mass flow by fluid.A new force—Coriolis force (picture 1) would be appear while two conditions met: (1) vibrating with normal frequency in a pair of bended tubes, (2) fluid flowing in tubes. This force was produced upon synthesis from vibrating force and flowing force by fluid in tubes. And tubes would be wresting symmetric the center line because the force forced (picture2). Two displacement sensors on sides of tubes detect the force and output electric signals. The signals regulated, mass flow directly produced (picture3).Â
Density measuring: Mediums of different density flow through the sensor, the vibration frequency of the vibration pipe is different, so can calculate the medium density by the vibration frequency.Â
Temperature measuring: Platinum resistance Installed on the sensor vibration pipe can indirectly measured the temperature of the medium.
Â
SDEC Diesel Generator
Petrol Generator,Cummins Diesel Generator Co., Ltd. , http://www.chpowergenerator.com